xFusion Server iBMC Template
Macros used
| Name | Value |
|---|---|
| {$SNMP_COMMUNITY} | Admin@9000 |
| {$SNMP_PORT} | 161 |
Items collected
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| averagePower | - | SNMP_AGENT | 600s | averagePower |
| cpuEntireStatus | Information about all cpu health status. | SNMP_AGENT | 600s | cpuEntireStatus |
| deviceName | The device name value between 1 to 63 characters. | SNMP_AGENT | 86400s | deviceName |
| deviceSerialNo | The device serial number value between 1 to 63 characters. | SNMP_AGENT | 60s | deviceSerialNo |
| diskPartitionUsagethreshold | Percent of hard disk partition usage threshold. This value is in [0,100]. | SNMP_AGENT | 600s | diskPartitionUsage |
| ethMACAddress | Information about MAC address. | SNMP_AGENT | 86400s | ethMACAddress |
| fanEntireStatus | Information about all fan health status. | SNMP_AGENT | 600s | fanEntireStatus |
| hardDiskEntireStatus | Information about all hard disk health status. | SNMP_AGENT | 600s | hardDiskEntireStatus |
| hostName | The host name between 1 to 64 characters. Supported characters: 0-9 a-z A-Z - ('-' is not allowed to be the first/last character). Default value is xFusion. | SNMP_AGENT | 86400s | hostName |
| memoryEntireStatus | Information about all memory health status. | SNMP_AGENT | 600s | memoryEntireStatus |
| OCPCardEntireStatus | - | SNMP_AGENT | 600s | OCPCardEntireStatus |
| OCPCardMaxNum | - | SNMP_AGENT | 600s | OCPCardMaxNum |
| PCIeDeviceEntireStatus | Information about all PCIe health status. | SNMP_AGENT | 600s | PCIeDeviceEntireStatus |
| PCIeDeviceMaxNum | Maximum number of PCIe cards.. | SNMP_AGENT | 600s | PCIeDeviceMaxNum |
| peakPower | System peak power, unit is W. | SNMP_AGENT | 600s | peakPower |
| powerConsumption(kWh) | Power consume from power statistic start time, unit is kWh. | SNMP_AGENT | 600s | powerConsumption |
| powerSupplyEntireStatus | Information about all power supply health status. | SNMP_AGENT | 600s | powerSupplyEntireStatus |
| presentSystemPower | Display the present system power. | SNMP_AGENT | 600s | presentSystemPower |
| sysName | An administratively-assigned name for this managed node. By convention, this is the node's fully-qualified domain name. | SNMP_AGENT | 86400s | sysName |
| systemCpuUsage | Percent of CPU usage. The value defined as: -1: invalid current CPU usage. [0,100]: represents the current CPU usage. | SNMP_AGENT | 600s | systemCpuUsage |
| systemGuid | - | SNMP_AGENT | 86400s | systemGuid |
| systemHealth | systemHealth information about system present state of health. This value will be one of the following: (1-OK, 2-Minor, 3-Major, 4-Critical) | SNMP_AGENT | 600s | systemHealth |
| systemMemUsage | Percent of memory usage. The value defined as: -1: invalid current memory usage. [0,100]: represents the current memory usage. | SNMP_AGENT | 600s | systemMemUsage |
| Inlet Temperature(°C) | If power off, the CPU temperature cannot be readable and is set to 65535. | SNMP_AGENT | 600s | temperatureValue |
Triggers
| Name | Description | Expression | Priority | Dependencies |
|---|---|---|---|---|
| Server {HOST.NAME} No data for > 5 minutes | Abnormal BMC connection, please check the network interface of the network card | nodata(/xFusion Server iBMC Template/deviceSerialNo,300s)=1 | HIGH ⛔ | deviceSerialNo |
| systemHealth Critical | systemHealth information about system present state of health. This value will be one of the following: (1-OK, 2-Minor, 3-Major, 4-Critical) | last(/xFusion Server iBMC Template/systemHealth)=4 | DISASTER 🔥 | systemHealth |
| systemHealth major | systemHealth information about system present state of health. This value will be one of the following: (1-OK, 2-Minor, 3-Major, 4-Critical) | last(/xFusion Server iBMC Template/systemHealth)=3 | HIGH ⛔ | systemHealth |
| systemHealth minor | systemHealth information about system present state of health. | last(/xFusion Server iBMC Template/systemHealth)=2 | WARNING 📢 | systemHealth |
Discovery rule №1
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| businessPortBDF | Business portBDF | SNMP_AGENT | 3600s | businessPortBDF-[{#SNMPINDEX}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| businessPort [{#SNMPINDEX}] BDF | Business portBDF | SNMP_AGENT | 86400s | businessPortBDF[{#SNMPINDEX}] |
Discovery rule №2
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| businessPortLinkStatus | - | SNMP_AGENT | 60s | businessPortLinkStatus-[{#SNMPINDEX}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| BusinessPort[{#SNMPINDEX}] LinkStatus | - | SNMP_AGENT | 600s | BusinessPortLinkStatus[{#SNMPINDEX}] |
Trigger prototypes
| Name | Description | Expression | Priority | Dependencies |
|---|---|---|---|---|
| BusinessPort[{#SNMPINDEX}] Disconnected | - | last(/xFusion Server iBMC Template/BusinessPortLinkStatus[{#SNMPINDEX}])="Disconnected" and change(/xFusion Server iBMC Template/BusinessPortLinkStatus[{#SNMPINDEX}])=1 | WARNING 📢 | BusinessPort[{#SNMPINDEX}] LinkStatus |
Discovery rule №3
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| businessPortLocation | Information about businessport belongs to which netcard. | SNMP_AGENT | 3600s | businessPortLocation-[{#SNMPINDEX}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| businessPort [{#SNMPINDEX}] Location | Information about businessport belongs to which netcard. | SNMP_AGENT | 86400s | businessPortLocation[{#SNMPINDEX}] |
Discovery rule №4
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| businessPortMacAddr | Business port MAC address. | SNMP_AGENT | 3600s | businessPortMacAddr-[{#SNMPINDEX}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| BusinessPort[{#SNMPINDEX}] MacAddr | Business port MAC address. | SNMP_AGENT | 86400s | businessPortMacAddr[{#SNMPINDEX}] |
Discovery rule №5
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| businessPortOSLinkStatus | Business port link status reported by OS. The status will be N/A if iBMA is not installed. | SNMP_AGENT | 3600s | businessPortOSLinkStatus-[{#SNMPINDEX}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| businessPort [{#SNMPINDEX}] OSLinkStatus | Business port link status reported by OS. The status will be N/A if iBMA is not installed. | SNMP_AGENT | 600s | businessPortOSLinkStatus[{#SNMPINDEX}] |
Trigger prototypes
| Name | Description | Expression | Priority | Dependencies |
|---|---|---|---|---|
| BusinessPort[{#SNMPINDEX}] OSLinkStatus | - | last(/xFusion Server iBMC Template/businessPortOSLinkStatus[{#SNMPINDEX}])="Disconnected" and change(/xFusion Server iBMC Template/businessPortOSLinkStatus[{#SNMPINDEX}])=1 | WARNING 📢 | businessPort [{#SNMPINDEX}] OSLinkStatus |
Discovery rule №6
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| businessPortSilkNum | Information about business port silk number within a netcard. | SNMP_AGENT | 3600s | businessPortSilkNum-[{#SNMPINDEX}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| businessPort {#SNMPVALUE} SilkNum | Information about business port silk number within a netcard. | SNMP_AGENT | 86400s | businessPortSilkNum[{#SNMPVALUE}] |
Discovery rule №7
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| cpuClockRate | Information about CPU clock rate | SNMP_AGENT | 3600s | cpuClockRate-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| cpu {#SNMPVALUE} ClockRate | - | SNMP_AGENT | 86400s | cpuClockRate[{#SNMPVALUE}] |
Discovery rule №8
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| cpuFamily | Information about CPU family | SNMP_AGENT | 3600s | cpuFamily-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| cpu {#SNMPVALUE} Family | - | SNMP_AGENT | 86400s | cpuFamily[{#SNMPVALUE}] |
Discovery rule №9
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| cpuManufacturer | Information about CPU manufacturer | SNMP_AGENT | 3600s | cpuManufacturer-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| cpu {#SNMPVALUE} Manufacturer | - | SNMP_AGENT | 86400s | cpuManufacturer[{#SNMPVALUE}] |
Discovery rule №10
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| cpuStatus | Information about CPU health status. | SNMP_AGENT | 3600s | cpuStatus-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| cpu {#SNMPVALUE} Status | Information about CPU health status. | SNMP_AGENT | 600s | cpuStatus[{#SNMPVALUE}] |
Trigger prototypes
| Name | Description | Expression | Priority | Dependencies |
|---|---|---|---|---|
| cpu [{#SNMPVALUE}] status critical | - | last(/xFusion Server iBMC Template/cpuStatus[{#SNMPVALUE}])=4 | DISASTER 🔥 | cpu {#SNMPVALUE} Status |
| cpu [{#SNMPVALUE}] status major | - | last(/xFusion Server iBMC Template/cpuStatus[{#SNMPVALUE}])=3 | HIGH ⛔ | cpu {#SNMPVALUE} Status |
| cpu [{#SNMPVALUE}] status minor | - | last(/xFusion Server iBMC Template/cpuStatus[{#SNMPVALUE}])=2 | WARNING 📢 | cpu {#SNMPVALUE} Status |
Discovery rule №11
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| cpuType | Information about CPU type | SNMP_AGENT | 3600s | cpuType-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| cpu {#SNMPVALUE} Type | - | SNMP_AGENT | 86400s | cpuType[{#SNMPVALUE}] |
Discovery rule №12
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| fanSpeed | - | SNMP_AGENT | 3600s | fanSpeed-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| fan {#SNMPVALUE} Speed | - | SNMP_AGENT | 600s | fanSpeed[{#SNMPVALUE}] |
Discovery rule №13
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| fanStatus | - | SNMP_AGENT | 3600s | fanStatus-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| fan {#SNMPVALUE} Status | - | SNMP_AGENT | 600s | fanStatus[{#SNMPVALUE}] |
Trigger prototypes
| Name | Description | Expression | Priority | Dependencies |
|---|---|---|---|---|
| fan [{#SNMPVALUE}] status critical | - | last(/xFusion Server iBMC Template/fanStatus[{#SNMPVALUE}])=4 | DISASTER 🔥 | fan {#SNMPVALUE} Status |
| fan [{#SNMPVALUE}] status major | - | last(/xFusion Server iBMC Template/fanStatus[{#SNMPVALUE}])=3 | HIGH ⛔ | fan {#SNMPVALUE} Status |
| fan [{#SNMPVALUE}] status minor | - | last(/xFusion Server iBMC Template/fanStatus[{#SNMPVALUE}])=2 | WARNING 📢 | fan {#SNMPVALUE} Status |
Discovery rule №14
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| firmwareLocation | Information about firmware location | SNMP_AGENT | 3600s | firmwareLocation-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| firmware {#SNMPVALUE} Location | - | SNMP_AGENT | 86400s | firmwareLocation[{#SNMPVALUE}] |
Discovery rule №15
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| firmwareReleaseDate | Information about firmware release date. | SNMP_AGENT | 3600s | firmwareReleaseDate-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| firmware {#SNMPVALUE} ReleaseDate | - | SNMP_AGENT | 86400s | firmwareReleaseDate[{#SNMPVALUE}] |
Discovery rule №16
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| firmwareVersion | - | SNMP_AGENT | 3600s | firmwareVersion-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| firmware {#SNMPVALUE} Version | firmware Version | SNMP_AGENT | 86400s | firmwareVersion[{#SNMPVALUE}] |
Discovery rule №17
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| hardDiskCapacityInGB(GB) | - | SNMP_AGENT | 3600s | hardDiskCapacityInGB-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| hardDisk {#SNMPVALUE} CapacityInGB(GB) | Hard disk capacity (GB) 1:unknown(-1) | SNMP_AGENT | 86400s | hardDiskCapacityInGB[{#SNMPVALUE}] |
Discovery rule №18
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| hardDiskManufacturer | - | SNMP_AGENT | 3600s | hardDiskManufacturer-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| hardDisk {#SNMPVALUE} Manufacturer | - | SNMP_AGENT | 86400s | hardDiskManufacturer[{#SNMPVALUE}] |
Discovery rule №19
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| hardDiskModelNumber | Harddisk model number. | SNMP_AGENT | 3600s | hardDiskModelNumber-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| hardDisk {#SNMPVALUE} ModelNumber | Harddisk model number. | SNMP_AGENT | 86400s | hardDiskModelNumber[{#SNMPVALUE}] |
Discovery rule №20
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| hardDiskSerialNumber | Harddisk serial number. | SNMP_AGENT | 3600s | hardDiskSerialNumber-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| hardDisk {#SNMPVALUE} Serial Number | Harddisk serial number. | SNMP_AGENT | 86400s | hardDiskSerialNumber[{#SNMPVALUE}] |
Discovery rule №21
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| hardDiskStatus | - | SNMP_AGENT | 3600s | hardDiskStatus-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| hardDisk {#SNMPVALUE} Status | - | SNMP_AGENT | 600s | hardDiskStatus[{#SNMPVALUE}] |
Trigger prototypes
| Name | Description | Expression | Priority | Dependencies |
|---|---|---|---|---|
| hardDisk [{#SNMPVALUE}] status critical | - | last(/xFusion Server iBMC Template/hardDiskStatus[{#SNMPVALUE}])=4 | DISASTER 🔥 | hardDisk {#SNMPVALUE} Status |
| hardDisk [{#SNMPVALUE}] status major | - | last(/xFusion Server iBMC Template/hardDiskStatus[{#SNMPVALUE}])=3 | HIGH ⛔ | hardDisk {#SNMPVALUE} Status |
| hardDisk [{#SNMPVALUE}] status minor | - | last(/xFusion Server iBMC Template/hardDiskStatus[{#SNMPVALUE}])=2 | WARNING 📢 | hardDisk {#SNMPVALUE} Status |
Discovery rule №22
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| logicalDriveName | Information about logical drive name.[X.y]X represents the number of the raid card, y represents the number of the logical drive, such as 0, 1, 2 | SNMP_AGENT | 3600s | logicalDriveName-[{#SNMPINDEX}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| logicalDrive {#SNMPINDEX} Name | Information about logical drive name,[x.y]X represents the number of the raid card, y represents the number of the logical drive, such as 0, 1, 2 | SNMP_AGENT | 86400s | logicalDriveName[{#SNMPINDEX}] |
Discovery rule №23
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| logicalDriveRaidLevel | Information about logical drive RAID level.[x.y]X represents the number of the raid card, y represents the number of the logical drive, such as 0, 1, 2 | SNMP_AGENT | 3600s | logicalDriveRaidLevel-[{#SNMPINDEX}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| logicalDrive {#SNMPINDEX} RAIDLevel | Information about logical drive RAID level.[x.y]X represents the number of the raid card, y represents the number of the logical drive, such as 0, 1, 2 | SNMP_AGENT | 86400s | logicalDriveRAIDLevel[{#SNMPINDEX}] |
Discovery rule №24
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| logicalDriveSize(MB) | Information about logical drive size,[x.y]X represents the number of the raid card, y represents the number of the logical drive, such as 0, 1, 2 | SNMP_AGENT | 3600s | logicalDriveSize-[{#SNMPINDEX}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| logicalDrive {#SNMPINDEX} Size(MB) | Information about logical drive size (MB).[x.y]X represents the number of the raid card, y represents the number of the logical drive, such as 0, 1, 2 | SNMP_AGENT | 86400s | logicalDriveSize[{#SNMPINDEX}] |
Discovery rule №25
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| logicalDriveState | Information about logical drive state,[X.y]X represents the number of the raid card, y represents the number of the logical drive, such as 0, 1, 2 | SNMP_AGENT | 3600s | logicalDriveState-[{#SNMPINDEX}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| logicalDrive {#SNMPINDEX} State | Information about logical drive state,[X.y]X represents the number of the raid card, y represents the number of the logical drive, such as 0, 1, 2 | SNMP_AGENT | 86400s | logicalDriveState[{#SNMPINDEX}] |
Trigger prototypes
| Name | Description | Expression | Priority | Dependencies |
|---|---|---|---|---|
| logicalDrive[{#SNMPVALUE}] state critical | - | in(last(/xFusion Server iBMC Template/logicalDriveState[{#SNMPINDEX}]),1,5,15,25,28)=4 | DISASTER 🔥 | logicalDrive {#SNMPINDEX} State |
| logicalDrive[{#SNMPVALUE}] state minor | - | in(last(/xFusion Server iBMC Template/logicalDriveState[{#SNMPINDEX}]),2,3,6,7,8,9,10,11,12,13,14,16,17,20,21)=2 | WARNING 📢 | logicalDrive {#SNMPINDEX} State |
Discovery rule №26
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| memoryClockRate | Information about memory clock rate.The units MHz. | SNMP_AGENT | 3600s | memoryClockRate-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| memory {#SNMPVALUE} ClockRate | Information about memory clock rate.The units MHz. | SNMP_AGENT | 86400s | memoryClockRate[{#SNMPVALUE}] |
Discovery rule №27
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| memoryManufacturer | - | SNMP_AGENT | 3600s | memoryManufacturer-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| memory {#SNMPVALUE} Manufacturer | Information about memory manufacturer. | SNMP_AGENT | 86400s | memoryManufacturer[{#SNMPVALUE}] |
Discovery rule №28
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| memorySize | - | SNMP_AGENT | 3600s | memorySize-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| memory {#SNMPVALUE} Size | Information about memory capacity. | SNMP_AGENT | 86400s | MemorySize[{#SNMPVALUE}] |
Discovery rule №29
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| memoryStatus | - | SNMP_AGENT | 3600s | memoryStatus-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| memory {#SNMPVALUE} Status | - | SNMP_AGENT | 600s | memoryStatus[{#SNMPVALUE}] |
Trigger prototypes
| Name | Description | Expression | Priority | Dependencies |
|---|---|---|---|---|
| memory [{#SNMPVALUE}] status critical | - | last(/xFusion Server iBMC Template/memoryStatus[{#SNMPVALUE}])=4 | DISASTER 🔥 | memory {#SNMPVALUE} Status |
| memory [{#SNMPVALUE}] status major | - | last(/xFusion Server iBMC Template/memoryStatus[{#SNMPVALUE}])=3 | HIGH ⛔ | memory {#SNMPVALUE} Status |
| memory [{#SNMPVALUE}] status minor | - | last(/xFusion Server iBMC Template/memoryStatus[{#SNMPVALUE}])=2 | WARNING 📢 | memory {#SNMPVALUE} Status |
Discovery rule №30
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| netCardLocation | Netcard physical Location. | SNMP_AGENT | 3600s | netCardLocation-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| netCard {#SNMPVALUE} Location | Netcard physical Location. | SNMP_AGENT | 86400s | NetCardLocation[{#SNMPVALUE}] |
Discovery rule №31
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| netCardNICName | - | SNMP_AGENT | 3600s | netCardNICName-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| netCardNIC {#SNMPVALUE} Name | - | SNMP_AGENT | 86400s | netCardNICName[{#SNMPVALUE}] |
Discovery rule №32
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| netCardStatus | - | SNMP_AGENT | 3600s | netCardStatus-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| netCard {#SNMPVALUE} Status | - | SNMP_AGENT | 600s | netCardStatus[{#SNMPVALUE}] |
Trigger prototypes
| Name | Description | Expression | Priority | Dependencies |
|---|---|---|---|---|
| netCard [{#SNMPVALUE}] status critical | - | last(/xFusion Server iBMC Template/netCardStatus[{#SNMPVALUE}])=4 | DISASTER 🔥 | netCard {#SNMPVALUE} Status |
| netCard [{#SNMPVALUE}] status major | - | last(/xFusion Server iBMC Template/netCardStatus[{#SNMPVALUE}])=3 | HIGH ⛔ | netCard {#SNMPVALUE} Status |
| netCard [{#SNMPVALUE}] status minor | - | last(/xFusion Server iBMC Template/netCardStatus[{#SNMPVALUE}])=2 | WARNING 📢 | netCard {#SNMPVALUE} Status |
Discovery rule №33
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCardAvailability | - | SNMP_AGENT | 3600s | OCPCardAvailability-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCard {#SNMPVALUE} Availability | - | SNMP_AGENT | 86400s | OCPCardAvailability[{#SNMPVALUE}] |
Discovery rule №34
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCardDescription | - | SNMP_AGENT | 3600s | OCPCardDescription-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCard {#SNMPVALUE} Description | - | SNMP_AGENT | 86400s | OCPCardDescription[{#SNMPVALUE}] |
Discovery rule №35
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCardDID | - | SNMP_AGENT | 3600s | OCPCardDID-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCard {#SNMPVALUE} DID | - | SNMP_AGENT | 86400s | OCPCardDID[{#SNMPVALUE}] |
Discovery rule №36
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCardFunction | - | SNMP_AGENT | 3600s | OCPCardFunction-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCard {#SNMPVALUE} Function | - | SNMP_AGENT | 86400s | OCPCardFunction[{#SNMPVALUE}] |
Discovery rule №37
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCardLocation | - | SNMP_AGENT | 3600s | OCPCardLocation-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCard {#SNMPVALUE} Location | - | SNMP_AGENT | 86400s | OCPCardLocation[{#SNMPVALUE}] |
Discovery rule №38
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCardManufacturer | - | SNMP_AGENT | 3600s | OCPCardManufacturer-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCard {#SNMPVALUE} Manufacturer | - | SNMP_AGENT | 86400s | OCPCardManufacturer[{#SNMPVALUE}] |
Discovery rule №39
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCardName | - | SNMP_AGENT | 3600s | OCPCardName-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCard {#SNMPVALUE} Name | - | SNMP_AGENT | 86400s | OCPCardName[{#SNMPVALUE}] |
Discovery rule №40
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCardPresence | - | SNMP_AGENT | 3600s | OCPCardPresence-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCard {#SNMPVALUE} Presence | - | SNMP_AGENT | 86400s | OCPCardPresence[{#SNMPVALUE}] |
Discovery rule №41
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCardStatus | - | SNMP_AGENT | 3600s | OCPCardStatus-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCard {#SNMPVALUE} Status | - | SNMP_AGENT | 600s | OCPCardStatus[{#SNMPVALUE}] |
Trigger prototypes
| Name | Description | Expression | Priority | Dependencies |
|---|---|---|---|---|
| OCPCard [{#SNMPVALUE}] status critical | - | last(/xFusion Server iBMC Template/OCPCardStatus[{#SNMPVALUE}])=4 | DISASTER 🔥 | OCPCard {#SNMPVALUE} Status |
| OCPCard [{#SNMPVALUE}] status major | - | last(/xFusion Server iBMC Template/OCPCardStatus[{#SNMPVALUE}])=3 | HIGH ⛔ | OCPCard {#SNMPVALUE} Status |
| OCPCard [{#SNMPVALUE}] status minor | - | last(/xFusion Server iBMC Template/OCPCardStatus[{#SNMPVALUE}])=2 | WARNING 📢 | OCPCard {#SNMPVALUE} Status |
Discovery rule №42
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCardVID | - | SNMP_AGENT | 3600s | OCPCardVID-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| OCPCard {#SNMPVALUE} VID | - | SNMP_AGENT | 86400s | OCPCardVID[{#SNMPVALUE}] |
Discovery rule №43
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDeviceAvailability | - | SNMP_AGENT | 3600s | PCIeDeviceAvailability-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDevice {#SNMPVALUE} Availability | - | SNMP_AGENT | 86400s | PCIeDeviceAvailability[{#SNMPVALUE}] |
Discovery rule №44
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDeviceDescription | - | SNMP_AGENT | 3600s | PCIeDeviceDescription-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDevice {#SNMPVALUE} Description | - | SNMP_AGENT | 86400s | PCIeDeviceDescription[{#SNMPVALUE}] |
Discovery rule №45
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDeviceDevicename | - | SNMP_AGENT | 3600s | PCIeDeviceDevicename-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDevice {#SNMPVALUE} Devicename | - | SNMP_AGENT | 86400s | PCIeDeviceDevicename[{#SNMPVALUE}] |
Discovery rule №46
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDeviceDID | - | SNMP_AGENT | 3600s | PCIeDeviceDID-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDevice {#SNMPVALUE} DID | - | SNMP_AGENT | 86400s | PCIeDeviceDID[{#SNMPVALUE}] |
Discovery rule №47
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDeviceFunction | - | SNMP_AGENT | 3600s | PCIeDeviceFunction-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDevice {#SNMPVALUE} Function | - | SNMP_AGENT | 86400s | PCIeDeviceFunction[{#SNMPVALUE}] |
Discovery rule №48
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDeviceLocation | - | SNMP_AGENT | 3600s | PCIeDeviceLocation-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDevice {#SNMPVALUE} Location | - | SNMP_AGENT | 86400s | PCIeDeviceLocation[{#SNMPVALUE}] |
Discovery rule №49
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDeviceManufacturer | - | SNMP_AGENT | 3600s | PCIeDeviceManufacturer-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDevice {#SNMPVALUE} Manufacturer | - | SNMP_AGENT | 86400s | PCIeDeviceManufacturer[{#SNMPVALUE}] |
Discovery rule №50
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDevicePresence | - | SNMP_AGENT | 3600s | PCIeDevicePresence-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDevice {#SNMPVALUE} Presence | Information about PCIe presence. | SNMP_AGENT | 86400s | PCIeDevicePresence[{#SNMPVALUE}] |
Discovery rule №51
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDeviceStatus | - | SNMP_AGENT | 3600s | PCIeDeviceStatus-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDevice {#SNMPVALUE} Status | - | SNMP_AGENT | 600s | PCIeDeviceStatus[{#SNMPVALUE}] |
Trigger prototypes
| Name | Description | Expression | Priority | Dependencies |
|---|---|---|---|---|
| PCIeDevice [{#SNMPVALUE}] status critical | - | last(/xFusion Server iBMC Template/PCIeDeviceStatus[{#SNMPVALUE}])=4 | DISASTER 🔥 | PCIeDevice {#SNMPVALUE} Status |
| PCIeDevice [{#SNMPVALUE}] status major | - | last(/xFusion Server iBMC Template/PCIeDeviceStatus[{#SNMPVALUE}])=3 | HIGH ⛔ | PCIeDevice {#SNMPVALUE} Status |
| PCIeDevice [{#SNMPVALUE}] status minor | - | last(/xFusion Server iBMC Template/PCIeDeviceStatus[{#SNMPVALUE}])=2 | WARNING 📢 | PCIeDevice {#SNMPVALUE} Status |
Discovery rule №52
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDeviceVID | - | SNMP_AGENT | 3600s | PCIeDeviceVID-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| PCIeDevice {#SNMPVALUE} VID | - | SNMP_AGENT | 86400s | PCIeDeviceVID[{#SNMPVALUE}] |
Discovery rule №53
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| powerSupplyInputPower | - | SNMP_AGENT | 3600s | powerSupplyInputPower-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| powerSupply {#SNMPVALUE} InputPower | - | SNMP_AGENT | 86400s | powerSupplyInputPower[{#SNMPVALUE}] |
Discovery rule №54
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| powerSupplyStatus | - | SNMP_AGENT | 3600s | powerSupplyStatus-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| powerSupply {#SNMPVALUE} Status | Information about power status. | SNMP_AGENT | 600s | powerSupplyStatus[{#SNMPVALUE}] |
Trigger prototypes
| Name | Description | Expression | Priority | Dependencies |
|---|---|---|---|---|
| powerSupply [{#SNMPVALUE}] status critical | - | last(/xFusion Server iBMC Template/powerSupplyStatus[{#SNMPVALUE}])=4 | DISASTER 🔥 | powerSupply {#SNMPVALUE} Status |
| powerSupply [{#SNMPVALUE}] status major | - | last(/xFusion Server iBMC Template/powerSupplyStatus[{#SNMPVALUE}])=3 | HIGH ⛔ | powerSupply {#SNMPVALUE} Status |
| powerSupply [{#SNMPVALUE}] status minor | - | last(/xFusion Server iBMC Template/powerSupplyStatus[{#SNMPVALUE}])=2 | WARNING 📢 | powerSupply {#SNMPVALUE} Status |
Discovery rule №55
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| raidControllerFwVersion | Information about RAID controller firmware version. | SNMP_AGENT | 3600s | raidControllerFwVersion-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| raidController {#SNMPVALUE} FwVersion | Information about RAID controller firmware version. | SNMP_AGENT | 86400s | raidControllerFwVersion[{#SNMPVALUE}] |
Discovery rule №56
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| raidControllerName | - | SNMP_AGENT | 3600s | raidControllerName-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| raidController {#SNMPVALUE} Name | Information about RAID controller name. | SNMP_AGENT | 86400s | raidControllerName[{#SNMPVALUE}] |
Discovery rule №57
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| raidControllerStatus | - | SNMP_AGENT | 3600s | raidControllerStatus-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| raidController {#SNMPVALUE} Status | - | SNMP_AGENT | 600s | raidControllerStatus[{#SNMPVALUE}] |
Trigger prototypes
| Name | Description | Expression | Priority | Dependencies |
|---|---|---|---|---|
| raidController [{#SNMPVALUE}] status major | - | (last(/xFusion Server iBMC Template/raidControllerStatus[{#SNMPVALUE}])>2 and last(/xFusion Server iBMC Template/raidControllerStatus[{#SNMPVALUE}])<16 ) or last(/xFusion Server iBMC Template/raidControllerStatus[{#SNMPVALUE}])=2 | HIGH ⛔ | raidController {#SNMPVALUE} Status |
| raidController [{#SNMPVALUE}] status minor | - | last(/xFusion Server iBMC Template/raidControllerStatus[{#SNMPVALUE}])=1 | WARNING 📢 | raidController {#SNMPVALUE} Status |
Discovery rule №58
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| temperature | If power off, the CPU temperature cannot be readable and is set to 65535. | SNMP_AGENT | 3600s | temperature-[{#SNMPVALUE}] |
Item prototypes
| Name | Description | Type | Interval | Key and additional info |
|---|---|---|---|---|
| {#SNMPITEM} Temperature(°C) | If power off, the CPU temperature cannot be readable and is set to 65535. | SNMP_AGENT | 600s | temperatureValue[{#SNMPVALUE}] |