Перейти к основному содержимому

HPE ProLiant BL460 SNMP

Macros used

NameValue
{$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"capacitorFailed"}7
{$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"failed"}4
{$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN:"degraded"}5
{$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN:"notPresent"}6
{$DISK.ARRAY.CACHE.STATUS.CRIT:"cacheModCriticalFailure"}8
{$DISK.ARRAY.CACHE.STATUS.OK:"enabled"}3
{$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModDegradedFailsafeSpeed"}7
{$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModFlashMemNotAttached"}6
{$DISK.ARRAY.CACHE.STATUS.WARN:"cacheReadCacheNotMapped"}9
{$DISK.ARRAY.CACHE.STATUS.WARN:"invalid"}2
{$DISK.ARRAY.STATUS.CRIT}4
{$DISK.ARRAY.STATUS.WARN}3
{$DISK.SMART.STATUS.FAIL:"replaceDrive"}3
{$DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}4
{$DISK.STATUS.FAIL}3
{$DISK.STATUS.WARN}4
{$FAN.STATUS.CRIT}4
{$FAN.STATUS.WARN}3
{$HEALTH.STATUS.CRIT}4
{$HEALTH.STATUS.WARN}3
{$PSU.STATUS.CRIT}4
{$PSU.STATUS.WARN}3
{$SNMP.TIMEOUT}5m
{$VDISK.STATUS.CRIT}3
{$VDISK.STATUS.OK}2

Items collected

NameDescriptionTypeIntervalKey and additional info
System contact detailsMIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.SNMP_AGENT1hhp.server.contact[sysContact]
System descriptionMIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software.SNMP_AGENT1hhp.server.descr[sysDescr]
Hardware model nameMIB: CPQSINFO-MIB The machine product name. The name of the machine used in this system.SNMP_AGENT

-

hp.server.hw.model[cpqSiProductName]
Hardware serial numberMIB: CPQSINFO-MIB The serial number of the physical system unit. The string will be empty if the system does not report the serial number function.SNMP_AGENT

-

hp.server.hw.serialnumber[cpqSiSysSerialNum]
System locationMIB: SNMPv2-MIB The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.SNMP_AGENT15mhp.server.location[sysLocation]
System nameMIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.SNMP_AGENT15mhp.server.name[sysName]
System object IDMIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determiningwhat kind of box' is being managed. For example, if vendorFlintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.SNMP_AGENT15mhp.server.objectid[sysObjectID]
System temperature statusMIB: CPQHLTH-MIB This value specifies the overall condition of the system's thermal environment. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within normal operating range. degraded(3) The temperature sensor is outside of normal operating range. failed(4) The temperature sensor detects a condition that could permanently damage the system.SNMP_AGENT

-

hp.server.sensor.temp.status[cpqHeThermalCondition]
Overall system health statusMIB: CPQHLTH-MIB The overall condition. This object represents the overall status of the server information represented by this MIB.SNMP_AGENT

-

hp.server.status[cpqHeMibCondition]
UptimeMIB: SNMPv2-MIB The time (in hundredths of a second) since the network management portion of the system was last re-initialized.SNMP_AGENT

-

hp.server.uptime[sysUpTime]
SNMP traps (fallback)The item is used to collect all SNMP traps unmatched by other snmptrap itemsSNMP_TRAP

-

snmptrap.fallback
SNMP agent availability

-

INTERNAL

-

zabbix[host,snmp,available]

Triggers

NameDescriptionExpressionPriorityDependencies
Device has been replacedDevice serial number has changed. Ack to closelast(/HPE ProLiant BL460 SNMP/hp.server.hw.serialnumber[cpqSiSysSerialNum],#1)<>last(/HPE ProLiant BL460 SNMP/hp.server.hw.serialnumber[cpqSiSysSerialNum],#2) and length(last(/HPE ProLiant BL460 SNMP/hp.server.hw.serialnumber[cpqSiSysSerialNum]))>0INFO 🔔Hardware serial number
System name has changedSystem name has changed. Ack to close.last(/HPE ProLiant BL460 SNMP/hp.server.name[sysName],#1)<>last(/HPE ProLiant BL460 SNMP/hp.server.name[sysName],#2) and length(last(/HPE ProLiant BL460 SNMP/hp.server.name[sysName]))>0INFO 🔔System name
System status is in critical statePlease check the device for errors.last(/HPE ProLiant BL460 SNMP/hp.server.status[cpqHeMibCondition])={$HEALTH.STATUS.CRIT}HIGH ⛔Overall system health status
System status is in warning statePlease check the device for warnings.last(/HPE ProLiant BL460 SNMP/hp.server.status[cpqHeMibCondition])={$HEALTH.STATUS.WARN}WARNING 📢Overall system health status
has been restartedUptime is less than 10 minutes.last(/HPE ProLiant BL460 SNMP/hp.server.uptime[sysUpTime])<10mWARNING 📢Uptime
No SNMP data collectionSNMP is not available for polling. Please check device connectivity and SNMP settings.max(/HPE ProLiant BL460 SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0WARNING 📢SNMP agent availability

Discovery rule №1

NameDescriptionTypeIntervalKey and additional info
Array controller cache discoveryScanning table of Array controllers: CPQIDA-MIB::cpqDaAccelTableSNMP_AGENT1harray.cache.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
#{#CACHE_CNTRL_INDEX}: Disk array cache controller battery statusMIB: CPQIDA-MIB Cache Module Board Backup Power Status. This monitors the status of each backup power source on the board. The backup power source can only recharge when the system has power applied. The type of backup power source used is indicated by cpqDaAccelBackupPowerSource. The following values are valid: Other (1) Indicates that the instrument agent does not recognize backup power status. You may need to update your software. Ok (2) The backup power source is fully charged. Recharging (3) The array controller has one or more cache module backup power sources that are recharging. Cache module operations such as Battery/Flash Backed Write Cache, Expansion, Extension and Migration are temporarily suspended until the backup power source is fully charged. Cache module operations will automatically resume when charging is complete. Failed (4) The battery pack is below the sufficient voltage level and has not recharged in 36 hours. Your Cache Module board needs to be serviced. Degraded (5) The battery is still operating, however, one of the batteries in the pack has failed to recharge properly. Your Cache Module board should be serviced as soon as possible. NotPresent (6) A backup power source is not present on the cache module board. Some controllers do not have backup power sources. Capacitor Failed (7) The flash backed cache module capacitor is below the sufficient voltage level and has not recharged in 10 minutes. Your Cache Module board needs to be serviced.SNMP_AGENT

-

hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}]
#{#CACHE_CNTRL_INDEX}: Disk array cache controller statusMIB: CPQIDA-MIB Cache Module/Operations Status. This describes the status of the cache module and/or cache operations. Note that for some controller models, a cache module board that physically attaches to the controller or chipset may not be an available option. The status can be: Other (1) Indicates that the instrument agent does not recognize the status of the cache module. You may need to upgrade the instrument agent. Invalid (2) Indicates that a cache module board has not been installed in this system or is present but not configured. Enabled (3) Indicates that cache operations are currently configured and enabled for at least one logical drive. Temporarily Disabled (4) Indicates that cache operations have been temporarily disabled. View the cache module board error code object to determine why the write cache operations have been temporarily disabled. Permanently Disabled (5) Indicates that cache operations have been permanently disabled. View the cache module board error code object to determine why the write cache operations have been disabled. Cache Module Flash Memory Not Attached (6) Indicates that the flash memory component of the flash backed cache module is not attached. This status will be set when the flash memory is not attached and the Supercap is attached. This value is only used on flash backed cache modules that support removable flash memory. Cache Module Degraded Failsafe Speed (7) Indicates that the cache module board is currently degraded and operating at a failsafe speed. View variables cpqDaCacheMemoryDataWidth and cpqDaCacheMemoryTransferRate to obtain the cache module board`s current memory data width and memory transfer rate. Cache Module Critical Failure (8) Indicates that the cache module board has encountered a critical failure. The controller is currently operating in Zero Memory Raid mode. Read Cache Could Not Be Mapped (9) Indicates that the read cache memory in a split cache configuration could not be mapped by the operating system and as a result is not available. This status may be caused by virtual space limitations in certain operating systems and is only applicable to B-Series controllers.SNMP_AGENT

-

hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
#{#CACHE_CNTRL_INDEX}: Disk array cache controller battery is in critical statePlease check the device for faults.last(/HPE ProLiant BL460 SNMP/hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"failed"} or last(/HPE ProLiant BL460 SNMP/hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.CRIT:"capacitorFailed"}AVERAGE ⚠#{#CACHE_CNTRL_INDEX}: Disk array cache controller battery status
#{#CACHE_CNTRL_INDEX}: Disk array cache controller battery is in warning statePlease check the device for faults.last(/HPE ProLiant BL460 SNMP/hp.server.hw.diskarray.cache.battery.status[cpqDaAccelBattery.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.BATTERY.STATUS.WARN:"degraded"}WARNING 📢#{#CACHE_CNTRL_INDEX}: Disk array cache controller battery status
#{#CACHE_CNTRL_INDEX}: Disk array cache controller is in critical state!Please check the device for faults.last(/HPE ProLiant BL460 SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.CRIT:"cacheModCriticalFailure"}AVERAGE ⚠#{#CACHE_CNTRL_INDEX}: Disk array cache controller status
#{#CACHE_CNTRL_INDEX}: Disk array cache controller is in warning statePlease check the device for faults.last(/HPE ProLiant BL460 SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModDegradedFailsafeSpeed"} or last(/HPE ProLiant BL460 SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheReadCacheNotMapped"} or last(/HPE ProLiant BL460 SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])={$DISK.ARRAY.CACHE.STATUS.WARN:"cacheModFlashMemNotAttached"}WARNING 📢#{#CACHE_CNTRL_INDEX}: Disk array cache controller status
#{#CACHE_CNTRL_INDEX}: Disk array cache controller is not in optimal statePlease check the device for faults.last(/HPE ProLiant BL460 SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.STATUS.OK:"enabled"} and last(/HPE ProLiant BL460 SNMP/hp.server.hw.diskarray.cache.status[cpqDaAccelStatus.{#SNMPINDEX}])<>{$DISK.ARRAY.CACHE.STATUS.WARN:"invalid"}WARNING 📢#{#CACHE_CNTRL_INDEX}: Disk array cache controller status

Discovery rule №2

NameDescriptionTypeIntervalKey and additional info
Array controller discoveryScanning table of Array controllers: CPQIDA-MIB::cpqDaCntlrTableSNMP_AGENT1harray.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
{#CNTLR_LOCATION}: Disk array controller modelMIB: CPQIDA-MIB Array Controller Model. The type of controller card.SNMP_AGENT

-

hp.server.hw.diskarray.model[cpqDaCntlrModel.{#SNMPINDEX}]
{#CNTLR_LOCATION}: Disk array controller statusMIB: CPQIDA-MIB This value represents the overall condition of this controller, and any associated logical drives, physical drives, and array accelerators.SNMP_AGENT

-

hp.server.hw.diskarray.status[cpqDaCntlrCondition.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
{#CNTLR_LOCATION}: Disk array controller is in critical statePlease check the device for faults.last(/HPE ProLiant BL460 SNMP/hp.server.hw.diskarray.status[cpqDaCntlrCondition.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.CRIT}HIGH ⛔{#CNTLR_LOCATION}: Disk array controller status
{#CNTLR_LOCATION}: Disk array controller is in warning statePlease check the device for faults.last(/HPE ProLiant BL460 SNMP/hp.server.hw.diskarray.status[cpqDaCntlrCondition.{#SNMPINDEX}])={$DISK.ARRAY.STATUS.WARN}AVERAGE ⚠{#CNTLR_LOCATION}: Disk array controller status

Discovery rule №3

NameDescriptionTypeIntervalKey and additional info
FAN discoveryCPQHLTH-MIB::cpqHeFltTolFanConditionSNMP_AGENT1hfan.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
Fan {#SNMPINDEX}: Fan statusMIB: CPQHLTH-MIB The condition of the fan. This value will be one of the following: other(1) Fan status detection is not supported by this system or driver. ok(2) The fan is operating properly. degraded(2) A redundant fan is not operating properly. failed(4) A non-redundant fan is not operating properly.SNMP_AGENT

-

hp.server.sensor.fan.status[cpqHeFltTolFanCondition.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
Fan {#SNMPINDEX}: Fan is in critical statePlease check the fan unit.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.fan.status[cpqHeFltTolFanCondition.{#SNMPINDEX}])={$FAN.STATUS.CRIT}AVERAGE ⚠Fan {#SNMPINDEX}: Fan status
Fan {#SNMPINDEX}: Fan is in warning statePlease check the fan unit.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.fan.status[cpqHeFltTolFanCondition.{#SNMPINDEX}])={$FAN.STATUS.WARN}WARNING 📢Fan {#SNMPINDEX}: Fan status

Discovery rule №4

NameDescriptionTypeIntervalKey and additional info
Network interface discoveryCPQIDA-MIB::cpqNicIfPhysAdapterTableSNMP_AGENT1hnet.if.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
{#ADAPTER_NAME} port {#ADAPTER_INDEX}: StatusMIB: CPQNIC-MIB The physical adapter status. The following values are valid: unknown(1) The instrument agent was not able to determine the status of the adapter. The instrument agent may need to be upgraded. ok(2) The physical adapter is operating properly. generalFailure(3) The physical adapter has failed. linkFailure(4) The physical adapter has lost link. Check the cable connections to this adapter.SNMP_AGENT

-

hp.server.net.if.status[cpqNicIfPhysAdapterStatus.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
{#ADAPTER_NAME} port {#ADAPTER_INDEX}: Adapter has failedPlease check the physical adapter.last(/HPE ProLiant BL460 SNMP/hp.server.net.if.status[cpqNicIfPhysAdapterStatus.{#SNMPINDEX}])=3HIGH ⛔{#ADAPTER_NAME} port {#ADAPTER_INDEX}: Status
{#ADAPTER_NAME} port {#ADAPTER_INDEX}: Adapter has lost linkPlease check the cable connections to this adapter.last(/HPE ProLiant BL460 SNMP/hp.server.net.if.status[cpqNicIfPhysAdapterStatus.{#SNMPINDEX}])=4AVERAGE ⚠{#ADAPTER_NAME} port {#ADAPTER_INDEX}: Status

Discovery rule №5

NameDescriptionTypeIntervalKey and additional info
Physical disk discoveryScanning table of physical drive entries CPQIDA-MIB::cpqDaPhyDrvTable.SNMP_AGENT1hphysicaldisk.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
{#DISK_LOCATION}: Physical disk media typeMIB: CPQIDA-MIB Drive Array Physical Drive Media Type. The following values are defined: other(1) The instrument agent is unable to determine the physical drive's media type. rotatingPlatters(2) The physical drive media is composed of rotating platters. solidState(3) The physical drive media is composed of solid state electronics.SNMP_AGENT

-

hp.server.hw.physicaldisk.media_type[cpqDaPhyDrvMediaType.{#SNMPINDEX}]
{#DISK_LOCATION}: Physical disk model nameMIB: CPQIDA-MIB Physical Drive Model. This is a text description of the physical drive. The text that appears depends upon who manufactured the drive and the drive type. If a drive fails, note the model to identify the type of drive necessary for replacement. If a model number is not present, you may not have properly initialized the drive array to which the physical drive is attached for monitoring.SNMP_AGENT

-

hp.server.hw.physicaldisk.model[cpqDaPhyDrvModel.{#SNMPINDEX}]
{#DISK_LOCATION}: Physical disk serial numberMIB: CPQIDA-MIB Physical Drive Serial Number. This is the serial number assigned to the physical drive. This value is based upon the serial number as returned by the SCSI inquiry command but may have been modified due to space limitations. This can be used for identification purposes.SNMP_AGENT

-

hp.server.hw.physicaldisk.serialnumber[cpqDaPhyDrvSerialNum.{#SNMPINDEX}]
{#DISK_LOCATION}: Disk sizeMIB: CPQIDA-MIB Physical Drive Size in MB. This is the size of the physical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers sometimes use the number 1,000,000 as a megabyte when giving drive capacities so this value may differ from the advertised size of a drive. This field is only applicable for controllers which support SCSI drives, and therefore is not supported by the IDA or IDA-2 controllers. The field will contain 0xFFFFFFFF if the drive capacity cannot be calculated or if the controller does not support SCSI drives.SNMP_AGENT

-

hp.server.hw.physicaldisk.size[cpqDaPhyDrvMediaType.{#SNMPINDEX}]
{#DISK_LOCATION}: Physical disk S.M.A.R.T. statusMIB: CPQIDA-MIB Physical Drive S.M.A.R.T Status. The following values are defined: other(1) The agent is unable to determine if the status of S.M.A.R.T predictive failure monitoring for this drive. ok(2) Indicates the drive is functioning properly. replaceDrive(3) Indicates that the drive has a S.M.A.R.T predictive failure error and should be replaced.SNMP_AGENT

-

hp.server.hw.physicaldisk.smart_status[cpqDaPhyDrvSmartStatus.{#SNMPINDEX}]
{#DISK_LOCATION}: Physical disk statusMIB: CPQIDA-MIB Physical Drive Status. This shows the status of the physical drive. The following values are valid for the physical drive status: other (1) Indicates that the instrument agent does not recognize the drive. You may need to upgrade your instrument agent and/or driver software. ok (2) Indicates the drive is functioning properly. failed (3) Indicates that the drive is no longer operating and should be replaced. predictiveFailure(4) Indicates that the drive has a predictive failure error and should be replaced.SNMP_AGENT

-

hp.server.hw.physicaldisk.status[cpqDaPhyDrvStatus.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
{#DISK_LOCATION}: Disk has been replacedDisk serial number has changed. Ack to closelast(/HPE ProLiant BL460 SNMP/hp.server.hw.physicaldisk.serialnumber[cpqDaPhyDrvSerialNum.{#SNMPINDEX}],#1)<>last(/HPE ProLiant BL460 SNMP/hp.server.hw.physicaldisk.serialnumber[cpqDaPhyDrvSerialNum.{#SNMPINDEX}],#2) and length(last(/HPE ProLiant BL460 SNMP/hp.server.hw.physicaldisk.serialnumber[cpqDaPhyDrvSerialNum.{#SNMPINDEX}]))>0INFO 🔔{#DISK_LOCATION}: Physical disk serial number
{#DISK_LOCATION}: Physical disk S.M.A.R.T. failedDisk probably requires replacement.last(/HPE ProLiant BL460 SNMP/hp.server.hw.physicaldisk.smart_status[cpqDaPhyDrvSmartStatus.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDrive"} or last(/HPE ProLiant BL460 SNMP/hp.server.hw.physicaldisk.smart_status[cpqDaPhyDrvSmartStatus.{#SNMPINDEX}])={$DISK.SMART.STATUS.FAIL:"replaceDriveSSDWearOut"}HIGH ⛔{#DISK_LOCATION}: Physical disk S.M.A.R.T. status
{#DISK_LOCATION}: Physical disk failedPlease check physical disk for warnings or errors.last(/HPE ProLiant BL460 SNMP/hp.server.hw.physicaldisk.status[cpqDaPhyDrvStatus.{#SNMPINDEX}])={$DISK.STATUS.FAIL}HIGH ⛔{#DISK_LOCATION}: Physical disk status
{#DISK_LOCATION}: Physical disk is in warning statePlease check physical disk for warnings or errors.last(/HPE ProLiant BL460 SNMP/hp.server.hw.physicaldisk.status[cpqDaPhyDrvStatus.{#SNMPINDEX}])={$DISK.STATUS.WARN}WARNING 📢{#DISK_LOCATION}: Physical disk status

Discovery rule №6

NameDescriptionTypeIntervalKey and additional info
PSU discoveryCPQHLTH-MIB::cpqHeFltTolPowerSupplyStatusSNMP_AGENT1hpsu.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply statusMIB: CPQHLTH-MIB The condition of the power supply. This value will be one of the following: other(1) The status could not be determined or not present. ok(2) The power supply is operating normally. degraded(3) A temperature sensor, fan or other power supply component is outside of normal operating range. failed(4) A power supply component detects a condition that could permanently damage the system.SNMP_AGENT

-

hp.server.sensor.psu.status[cpqHeFltTolPowerSupplyCondition.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply is in critical statePlease check the power supply unit for errors.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.psu.status[cpqHeFltTolPowerSupplyCondition.{#SNMPINDEX}])={$PSU.STATUS.CRIT}AVERAGE ⚠Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply status
Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply is in warning statePlease check the power supply unit for errors.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.psu.status[cpqHeFltTolPowerSupplyCondition.{#SNMPINDEX}])={$PSU.STATUS.WARN}WARNING 📢Chassis {#CHASSIS_NUM}, bay {#BAY_NUM}: Power supply status

Discovery rule №7

NameDescriptionTypeIntervalKey and additional info
Temperature ambient discoveryScanning table of Temperature Sensor Entries: CPQHLTH-MIB::cpqHeTemperatureTable with ambient(11) and 0.1 index filterSNMP_AGENT1htemp.ambient.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
Ambient: Temperature sensor conditionMIB: CPQHLTH-MIB The Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within normal operating range. degraded(3) The temperature sensor is outside of normal operating range. failed(4) The temperature sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.SNMP_AGENT

-

hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Ambient.{#SNMPINDEX}]
Ambient: TemperatureMIB: CPQHLTH-MIB Temperature readings of testpoint: AmbientSNMP_AGENT

-

hp.server.sensor.temp.value[cpqHeTemperatureCelsius.Ambient.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
Ambient: Temperature could not be determinedTemperature could not be determined.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Ambient.{#SNMPINDEX}]) = 1INFO 🔔Ambient: Temperature sensor condition
Ambient: The temperature sensor detects a condition that could permanently damage the system.The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Ambient.{#SNMPINDEX}]) = 4HIGH ⛔Ambient: Temperature sensor condition
Ambient: The temperature sensor is outside of normal operating rangeIf the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Ambient.{#SNMPINDEX}]) = 3WARNING 📢Ambient: Temperature sensor condition

Discovery rule №8

NameDescriptionTypeIntervalKey and additional info
Temperature CPU discoveryScanning table of Temperature Sensor Entries: CPQHLTH-MIB::cpqHeTemperatureTable with cpu(6) filterSNMP_AGENT1htemp.cpu.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
CPU-{#SNMPINDEX}: Temperature sensor conditionMIB: CPQHLTH-MIB The Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within normal operating range. degraded(3) The temperature sensor is outside of normal operating range. failed(4) The temperature sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.SNMP_AGENT

-

hp.server.sensor.temp.condition[cpqHeTemperatureCondition.CPU.{#SNMPINDEX}]
CPU-{#SNMPINDEX}: TemperatureMIB: CPQHLTH-MIB Temperature readings of testpoint: CPU-{#SNMPINDEX}SNMP_AGENT

-

hp.server.sensor.temp.value[cpqHeTemperatureCelsius.CPU.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
CPU-{#SNMPINDEX}: Temperature could not be determinedTemperature could not be determined.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.CPU.{#SNMPINDEX}]) = 1INFO 🔔CPU-{#SNMPINDEX}: Temperature sensor condition
CPU-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.CPU.{#SNMPINDEX}]) = 4HIGH ⛔CPU-{#SNMPINDEX}: Temperature sensor condition
CPU-{#SNMPINDEX}: The temperature sensor is outside of normal operating rangeIf the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.CPU.{#SNMPINDEX}]) = 3WARNING 📢CPU-{#SNMPINDEX}: Temperature sensor condition

Discovery rule №9

NameDescriptionTypeIntervalKey and additional info
Temperature discoveryScanning table of Temperature Sensor Entries: CPQHLTH-MIB::cpqHeTemperatureTableSNMP_AGENT1htemp.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
{#SNMPINDEX}: Temperature sensor conditionMIB: CPQHLTH-MIB The Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within normal operating range. degraded(3) The temperature sensor is outside of normal operating range. failed(4) The temperature sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.SNMP_AGENT

-

hp.server.sensor.temp.condition[cpqHeTemperatureCondition.{#SNMPINDEX}]
{#SNMPINDEX}: Temperature sensor locationMIB: CPQHLTH-MIB This specifies the location of the temperature sensor present in the system.SNMP_AGENT

-

hp.server.sensor.temp.locale[cpqHeTemperatureLocale.{#SNMPINDEX}]
{#SNMPINDEX}: TemperatureMIB: CPQHLTH-MIB Temperature readings of testpoint: {#SNMPINDEX}SNMP_AGENT

-

hp.server.sensor.temp.value[cpqHeTemperatureCelsius.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
{#SNMPINDEX}: Temperature could not be determinedTemperature could not be determined.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.{#SNMPINDEX}]) = 1INFO 🔔{#SNMPINDEX}: Temperature sensor condition
{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.{#SNMPINDEX}]) = 4HIGH ⛔{#SNMPINDEX}: Temperature sensor condition
{#SNMPINDEX}: The temperature sensor is outside of normal operating rangeIf the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.{#SNMPINDEX}]) = 3WARNING 📢{#SNMPINDEX}: Temperature sensor condition

Discovery rule №10

NameDescriptionTypeIntervalKey and additional info
Temperature I/O discoveryScanning table of Temperature Sensor Entries: CPQHLTH-MIB::cpqHeTemperatureTable with ioBoard(5) filterSNMP_AGENT1htemp.io.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
I/O-{#SNMPINDEX}: Temperature sensor conditionMIB: CPQHLTH-MIB The Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within normal operating range. degraded(3) The temperature sensor is outside of normal operating range. failed(4) The temperature sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.SNMP_AGENT

-

hp.server.sensor.temp.condition[cpqHeTemperatureCondition."I/O.{#SNMPINDEX}"]
I/O-{#SNMPINDEX}: TemperatureMIB: CPQHLTH-MIB Temperature readings of testpoint: I/O-{#SNMPINDEX}SNMP_AGENT

-

hp.server.sensor.temp.value[cpqHeTemperatureCelsius."I/O.{#SNMPINDEX}"]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
I/O-{#SNMPINDEX}: Temperature could not be determinedTemperature could not be determined.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition."I/O.{#SNMPINDEX}"]) = 1INFO 🔔I/O-{#SNMPINDEX}: Temperature sensor condition
I/O-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition."I/O.{#SNMPINDEX}"]) = 4HIGH ⛔I/O-{#SNMPINDEX}: Temperature sensor condition
I/O-{#SNMPINDEX}: The temperature sensor is outside of normal operating rangeIf the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition."I/O.{#SNMPINDEX}"]) = 3WARNING 📢I/O-{#SNMPINDEX}: Temperature sensor condition

Discovery rule №11

NameDescriptionTypeIntervalKey and additional info
Temperature memory discoveryScanning table of Temperature Sensor Entries: CPQHLTH-MIB::cpqHeTemperatureTable with memory(7) filterSNMP_AGENT1htemp.memory.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
Memory-{#SNMPINDEX}: Temperature sensor conditionMIB: CPQHLTH-MIB The Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within normal operating range. degraded(3) The temperature sensor is outside of normal operating range. failed(4) The temperature sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.SNMP_AGENT

-

hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Memory.{#SNMPINDEX}]
Memory-{#SNMPINDEX}: TemperatureMIB: CPQHLTH-MIB Temperature readings of testpoint: Memory-{#SNMPINDEX}SNMP_AGENT

-

hp.server.sensor.temp.value[cpqHeTemperatureCelsius.Memory.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
Memory-{#SNMPINDEX}: Temperature could not be determinedTemperature could not be determined.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Memory.{#SNMPINDEX}]) = 1INFO 🔔Memory-{#SNMPINDEX}: Temperature sensor condition
Memory-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Memory.{#SNMPINDEX}]) = 4HIGH ⛔Memory-{#SNMPINDEX}: Temperature sensor condition
Memory-{#SNMPINDEX}: The temperature sensor is outside of normal operating rangeIf the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.Memory.{#SNMPINDEX}]) = 3WARNING 📢Memory-{#SNMPINDEX}: Temperature sensor condition

Discovery rule №12

NameDescriptionTypeIntervalKey and additional info
Temperature PSU discoveryScanning table of Temperature Sensor Entries: CPQHLTH-MIB::cpqHeTemperatureTable with powerSupply(10) filterSNMP_AGENT1htemp.psu.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
PSU-{#SNMPINDEX}: Temperature sensor conditionMIB: CPQHLTH-MIB The Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within normal operating range. degraded(3) The temperature sensor is outside of normal operating range. failed(4) The temperature sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.SNMP_AGENT

-

hp.server.sensor.temp.condition[cpqHeTemperatureCondition.PSU.{#SNMPINDEX}]
PSU-{#SNMPINDEX}: TemperatureMIB: CPQHLTH-MIB Temperature readings of testpoint: PSU-{#SNMPINDEX}SNMP_AGENT

-

hp.server.sensor.temp.value[cpqHeTemperatureCelsius.PSU.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
PSU-{#SNMPINDEX}: Temperature could not be determinedTemperature could not be determined.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.PSU.{#SNMPINDEX}]) = 1INFO 🔔PSU-{#SNMPINDEX}: Temperature sensor condition
PSU-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.PSU.{#SNMPINDEX}]) = 4HIGH ⛔PSU-{#SNMPINDEX}: Temperature sensor condition
PSU-{#SNMPINDEX}: The temperature sensor is outside of normal operating rangeIf the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.PSU.{#SNMPINDEX}]) = 3WARNING 📢PSU-{#SNMPINDEX}: Temperature sensor condition

Discovery rule №13

NameDescriptionTypeIntervalKey and additional info
Temperature system discoveryScanning table of Temperature Sensor Entries: CPQHLTH-MIB::cpqHeTemperatureTable with system(3) filterSNMP_AGENT1htemp.system.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
System-{#SNMPINDEX}: Temperature sensor conditionMIB: CPQHLTH-MIB The Temperature sensor condition. This value will be one of the following: other(1) Temperature could not be determined. ok(2) The temperature sensor is within normal operating range. degraded(3) The temperature sensor is outside of normal operating range. failed(4) The temperature sensor detects a condition that could permanently damage the system. The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent. If the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.SNMP_AGENT

-

hp.server.sensor.temp.condition[cpqHeTemperatureCondition.System.{#SNMPINDEX}]
System-{#SNMPINDEX}: TemperatureMIB: CPQHLTH-MIB Temperature readings of testpoint: System-{#SNMPINDEX}SNMP_AGENT

-

hp.server.sensor.temp.value[cpqHeTemperatureCelsius.System.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
System-{#SNMPINDEX}: Temperature could not be determinedTemperature could not be determined.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.System.{#SNMPINDEX}]) = 1INFO 🔔System-{#SNMPINDEX}: Temperature sensor condition
System-{#SNMPINDEX}: The temperature sensor detects a condition that could permanently damage the system.The system will automatically shutdown if the failed(4) condition results, so it is unlikely that this value will ever be returned by the agent.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.System.{#SNMPINDEX}]) = 4HIGH ⛔System-{#SNMPINDEX}: Temperature sensor condition
System-{#SNMPINDEX}: The temperature sensor is outside of normal operating rangeIf the cpqHeThermalDegradedAction is set to shutdown(3) the system will be shutdown if the degraded(3) condition occurs.last(/HPE ProLiant BL460 SNMP/hp.server.sensor.temp.condition[cpqHeTemperatureCondition.System.{#SNMPINDEX}]) = 3WARNING 📢System-{#SNMPINDEX}: Temperature sensor condition

Discovery rule №14

NameDescriptionTypeIntervalKey and additional info
Virtual disk discoveryCPQIDA-MIB::cpqDaLogDrvTableSNMP_AGENT1hvirtualdisk.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
Disk {#SNMPINDEX}({#DISK_NAME}): Layout typeLogical Drive Fault Tolerance. This shows the fault tolerance mode of the logical drive.SNMP_AGENT

-

hp.server.hw.virtualdisk.layout[cpqDaLogDrvFaultTol.{#SNMPINDEX}]
Disk {#SNMPINDEX}({#DISK_NAME}): Disk sizeLogical Drive Size. This is the size of the logical drive in megabytes. This value is calculated using the value 1,048,576 (2^20) as a megabyte. Drive manufacturers sometimes use the number 1,000,000 as a megabyte when giving drive capacities so this value may differ from the advertised size of a drive.SNMP_AGENT

-

hp.server.hw.virtualdisk.size[cpqDaLogDrvSize.{#SNMPINDEX}]
Disk {#SNMPINDEX}({#DISK_NAME}): StatusLogical Drive Status.SNMP_AGENT

-

hp.server.hw.virtualdisk.status[cpqDaLogDrvStatus.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
Disk {#SNMPINDEX}({#DISK_NAME}): Virtual disk failedPlease check virtual disk for warnings or errors.last(/HPE ProLiant BL460 SNMP/hp.server.hw.virtualdisk.status[cpqDaLogDrvStatus.{#SNMPINDEX}])={$VDISK.STATUS.CRIT}HIGH ⛔Disk {#SNMPINDEX}({#DISK_NAME}): Status
Disk {#SNMPINDEX}({#DISK_NAME}): Virtual disk is not in OK statePlease check virtual disk for warnings or errors.last(/HPE ProLiant BL460 SNMP/hp.server.hw.virtualdisk.status[cpqDaLogDrvStatus.{#SNMPINDEX}])<>{$VDISK.STATUS.OK}WARNING 📢Disk {#SNMPINDEX}({#DISK_NAME}): Status