Перейти к основному содержимому

Arista SNMP

Macros used

NameValue
{$CPU.UTIL.CRIT}90
{$FAN_CRIT_STATUS}3
{$ICMP_LOSS_WARN}20
{$ICMP_RESPONSE_TIME_WARN}0.15
{$IF.ERRORS.WARN}2
{$IF.UTIL.MAX}90
{$IFCONTROL}1
{$MEMORY.NAME.MATCHES}.*
{$MEMORY.NAME.NOT_MATCHES}(Buffer|Cache)
{$MEMORY.TYPE.MATCHES}.*(.2|hrStorageRam)$
{$MEMORY.TYPE.NOT_MATCHES}CHANGE_IF_NEEDED
{$MEMORY.UTIL.MAX}90
{$NET.IF.IFADMINSTATUS.MATCHES}^.*
{$NET.IF.IFADMINSTATUS.NOT_MATCHES}^2$
{$NET.IF.IFALIAS.MATCHES}.*
{$NET.IF.IFALIAS.NOT_MATCHES}CHANGE_IF_NEEDED
{$NET.IF.IFDESCR.MATCHES}.*
{$NET.IF.IFDESCR.NOT_MATCHES}CHANGE_IF_NEEDED
{$NET.IF.IFNAME.MATCHES}^.*$
{$NET.IF.IFNAME.NOT_MATCHES}(^Software Loopback Interface|^NULL[0-9.]$|^[Ll]o[0-9.]$|^[Ss]ystem$|^Nu[0-9.]*$|^veth[0-9a-z]+$|docker[0-9]+|br-[a-z0-9]{12})
{$NET.IF.IFOPERSTATUS.MATCHES}^.*$
{$NET.IF.IFOPERSTATUS.NOT_MATCHES}^6$
{$NET.IF.IFTYPE.MATCHES}.*
{$NET.IF.IFTYPE.NOT_MATCHES}CHANGE_IF_NEEDED
{$PSU_CRIT_STATUS}2
{$SNMP.TIMEOUT}5m
{$VFS.FS.FREE.MIN.CRIT}5G
{$VFS.FS.FREE.MIN.WARN}10G
{$VFS.FS.FSNAME.MATCHES}.+
{$VFS.FS.FSNAME.NOT_MATCHES}^(/dev|/sys|/run|/proc|.+/shm$)
{$VFS.FS.FSTYPE.MATCHES}.*(.4|.9|hrStorageFixedDisk|hrStorageFlashMemory)$
{$VFS.FS.FSTYPE.NOT_MATCHES}CHANGE_IF_NEEDED
{$VFS.FS.PUSED.MAX.CRIT}95
{$VFS.FS.PUSED.MAX.WARN}90

Items collected

NameDescriptionTypeIntervalKey and additional info
ICMP ping

-

SIMPLE

-

icmpping
ICMP loss

-

SIMPLE

-

icmppingloss
ICMP response time

-

SIMPLE

-

icmppingsec
Get sensorsGets sensors with type, description, and thresholds.SNMP_AGENT1hsensors.get
SNMP traps (fallback)The item is used to collect all SNMP traps unmatched by other snmptrap itemsSNMP_TRAP

-

snmptrap.fallback
System contact detailsMIB: SNMPv2-MIB The textual identification of the contact person for this managed node, together with information on how to contact this person. If no contact information is known, the value is the zero-length string.SNMP_AGENT15msystem.contact[sysContact.0]
CPU utilizationMIB: HOST-RESOURCES-MIB The average, over the last minute, of the percentage of time that processors was not idle. Implementations may approximate this one minute smoothing period if necessary.SNMP_AGENT

-

system.cpu.util
System descriptionMIB: SNMPv2-MIB A textual description of the entity. This value should include the full name and version identification of the system's hardware type, software operating-system, and networking software.SNMP_AGENT15msystem.descr[sysDescr.0]
System locationMIB: SNMPv2-MIB The physical location of this node (e.g., `telephone closet, 3rd floor'). If the location is unknown, the value is the zero-length string.SNMP_AGENT15msystem.location[sysLocation.0]
System nameMIB: SNMPv2-MIB An administratively-assigned name for this managed node.By convention, this is the node's fully-qualified domain name. If the name is unknown, the value is the zero-length string.SNMP_AGENT15msystem.name
System object IDMIB: SNMPv2-MIB The vendor's authoritative identification of the network management subsystem contained in the entity. This value is allocated within the SMI enterprises subtree (1.3.6.1.4.1) and provides an easy and unambiguous means for determiningwhat kind of box' is being managed. For example, if vendorFlintstones, Inc.' was assigned the subtree1.3.6.1.4.1.4242, it could assign the identifier 1.3.6.1.4.1.4242.1.1 to its `Fred Router'.SNMP_AGENT15msystem.objectid[sysObjectID.0]
UptimeMIB: SNMPv2-MIB The time (in hundredths of a second) since the network management portion of the system was last re-initialized.SNMP_AGENT30ssystem.uptime[sysUpTime.0]
SNMP agent availabilityAvailability of SNMP checks on the host. The value of this item corresponds to availability icons in the host list. Possible value: 0 - not available 1 - available 2 - unknownINTERNAL

-

zabbix[host,snmp,available]

Triggers

NameDescriptionExpressionPriorityDependencies
Unavailable by ICMP pingLast three attempts returned timeout. Please check device connectivity.max(/Arista SNMP/icmpping,#3)=0HIGH ⛔ICMP ping
High ICMP ping loss

-

min(/Arista SNMP/icmppingloss,5m)>{$ICMP_LOSS_WARN} and min(/Arista SNMP/icmppingloss,5m)<100WARNING 📢ICMP loss
High ICMP ping response time

-

avg(/Arista SNMP/icmppingsec,5m)>{$ICMP_RESPONSE_TIME_WARN}WARNING 📢ICMP response time
High CPU utilizationCPU utilization is too high. The system might be slow to respond.min(/Arista SNMP/system.cpu.util,5m)>{$CPU.UTIL.CRIT}WARNING 📢CPU utilization
System name has changedSystem name has changed. Ack to close.last(/Arista SNMP/system.name,#1)<>last(/Arista SNMP/system.name,#2) and length(last(/Arista SNMP/system.name))>0INFO 🔔System name
has been restartedUptime is less than 10 minutes.last(/Arista SNMP/system.uptime[sysUpTime.0])<10mWARNING 📢Uptime
No SNMP data collectionSNMP is not available for polling. Please check device connectivity and SNMP settings.max(/Arista SNMP/zabbix[host,snmp,available],{$SNMP.TIMEOUT})=0WARNING 📢SNMP agent availability

Discovery rule №1

NameDescriptionTypeIntervalKey and additional info
Entity discovery

-

SNMP_AGENT1hentity.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
{#ENT_NAME}: Hardware model nameMIB: ENTITY-MIBSNMP_AGENT1hsystem.hw.model[entPhysicalModelName.{#SNMPINDEX}]
{#ENT_NAME}: Hardware serial numberMIB: ENTITY-MIBSNMP_AGENT1hsystem.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
{#ENT_NAME}: Device has been replacedDevice serial number has changed. Ack to closelast(/Arista SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}],#1)<>last(/Arista SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}],#2) and length(last(/Arista SNMP/system.hw.serialnumber[entPhysicalSerialNum.{#SNMPINDEX}]))>0INFO 🔔{#ENT_NAME}: Hardware serial number

Discovery rule №2

NameDescriptionTypeIntervalKey and additional info
Fan discoveryENTITY-SENSORS-MIB::EntitySensorDataType discovery with rpm filterDEPENDENT0fan.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
{#SENSOR_INFO}: Fan speedMIB: ENTITY-SENSORS-MIB The most recent measurement obtained by the agent for this sensor. To correctly interpret the value of this object, the associated entPhySensorType, entPhySensorScale, and entPhySensorPrecision objects must also be examined.SNMP_AGENT

-

sensor.fan.speed[entPhySensorValue.{#SNMPINDEX}]
{#SENSOR_INFO}: Fan statusMIB: ENTITY-SENSORS-MIB The operational status of the sensor {#SENSOR_INFO}SNMP_AGENT3msensor.fan.status[entPhySensorOperStatus.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
{#SENSOR_INFO}: Fan speed is above the critical thresholdThis trigger uses fan sensor values defined in the device.min(/Arista SNMP/sensor.fan.speed[entPhySensorValue.{#SNMPINDEX}],5m) > {#THRESHOLD_HI_CRIT}HIGH ⛔{#SENSOR_INFO}: Fan speed
{#SENSOR_INFO}: Fan speed is above the warning thresholdThis trigger uses fan sensor values defined in the device.min(/Arista SNMP/sensor.fan.speed[entPhySensorValue.{#SNMPINDEX}],5m) > {#THRESHOLD_HI_WARN}WARNING 📢{#SENSOR_INFO}: Fan speed
{#SENSOR_INFO}: Fan speed is below the critical thresholdThis trigger uses fan sensor values defined in the device.max(/Arista SNMP/sensor.fan.speed[entPhySensorValue.{#SNMPINDEX}],5m) < {#THRESHOLD_LO_CRIT}HIGH ⛔{#SENSOR_INFO}: Fan speed
{#SENSOR_INFO}: Fan speed is below the warning thresholdThis trigger uses fan sensor values defined in the device.max(/Arista SNMP/sensor.fan.speed[entPhySensorValue.{#SNMPINDEX}],5m) < {#THRESHOLD_LO_WARN}WARNING 📢{#SENSOR_INFO}: Fan speed
{#SENSOR_INFO}: Fan is in critical statePlease check the fan unitcount(/Arista SNMP/sensor.fan.status[entPhySensorOperStatus.{#SNMPINDEX}],#1,"eq","{$FAN_CRIT_STATUS}")=1AVERAGE ⚠{#SENSOR_INFO}: Fan status

Discovery rule №3

NameDescriptionTypeIntervalKey and additional info
Network interfaces discoveryDiscovering interfaces from IF-MIB.SNMP_AGENT1hnet.if.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
Interface {#IFNAME}({#IFALIAS}): Inbound packets discardedMIB: IF-MIB The number of inbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.SNMP_AGENT3mnet.if.in.discards[ifInDiscards.{#SNMPINDEX}]
Interface {#IFNAME}({#IFALIAS}): Inbound packets with errorsMIB: IF-MIB For packet-oriented interfaces, the number of inbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of inbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.SNMP_AGENT3mnet.if.in.errors[ifInErrors.{#SNMPINDEX}]
Interface {#IFNAME}({#IFALIAS}): Bits receivedMIB: IF-MIB The total number of octets received on the interface, including framing characters. This object is a 64-bit version of ifInOctets. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.SNMP_AGENT3mnet.if.in[ifHCInOctets.{#SNMPINDEX}]
Interface {#IFNAME}({#IFALIAS}): Outbound packets discardedMIB: IF-MIB The number of outbound packets which were chosen to be discarded even though no errors had been detected to prevent their being deliverable to a higher-layer protocol. One possible reason for discarding such a packet could be to free up buffer space. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.SNMP_AGENT3mnet.if.out.discards[ifOutDiscards.{#SNMPINDEX}]
Interface {#IFNAME}({#IFALIAS}): Outbound packets with errorsMIB: IF-MIB For packet-oriented interfaces, the number of outbound packets that contained errors preventing them from being deliverable to a higher-layer protocol. For character-oriented or fixed-length interfaces, the number of outbound transmission units that contained errors preventing them from being deliverable to a higher-layer protocol. Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.SNMP_AGENT3mnet.if.out.errors[ifOutErrors.{#SNMPINDEX}]
Interface {#IFNAME}({#IFALIAS}): Bits sentMIB: IF-MIB The total number of octets transmitted out of the interface, including framing characters. This object is a 64-bit version of ifOutOctets.Discontinuities in the value of this counter can occur at re-initialization of the management system, and at other times as indicated by the value of ifCounterDiscontinuityTime.SNMP_AGENT3mnet.if.out[ifHCOutOctets.{#SNMPINDEX}]
Interface {#IFNAME}({#IFALIAS}): SpeedMIB: IF-MIB An estimate of the interface's current bandwidth in units of 1,000,000 bits per second. If this object reports a value of n' then the speed of the interface is somewhere in the range of n-500,000' to`n+499,999'. For interfaces which do not vary in bandwidth or for those where no accurate estimation can be made, this object should contain the nominal bandwidth. For a sub-layer which has no concept of bandwidth, this object should be zero.SNMP_AGENT5mnet.if.speed[ifHighSpeed.{#SNMPINDEX}]
Interface {#IFNAME}({#IFALIAS}): Operational statusMIB: IF-MIB The current operational state of the interface. - The testing(3) state indicates that no operational packet scan be passed - If ifAdminStatus is down(2) then ifOperStatus should be down(2) - If ifAdminStatus is changed to up(1) then ifOperStatus should change to up(1) if the interface is ready to transmit and receive network traffic - It should change todormant(5) if the interface is waiting for external actions (such as a serial line waiting for an incoming connection) - It should remain in the down(2) state if and only if there is a fault that prevents it from going to the up(1) state - It should remain in the notPresent(6) state if the interface has missing(typically, hardware) components.SNMP_AGENT

-

net.if.status[ifOperStatus.{#SNMPINDEX}]
Interface {#IFNAME}({#IFALIAS}): Interface typeMIB: IF-MIB The type of interface. Additional values for ifType are assigned by the Internet Assigned Numbers Authority (IANA), through updating the syntax of the IANAifType textual convention.SNMP_AGENT1hnet.if.type[ifType.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
Interface {#IFNAME}({#IFALIAS}): Link downThis trigger expression works as follows: 1. Can be triggered if operations status is down. 2. {$IFCONTROL:"{#IFNAME}"}=1 - user can redefine Context macro to value - 0. That marks this interface as not important. No new trigger will be fired if this interface is down. 3. {TEMPLATE_NAME:METRIC.diff()}=1) - trigger fires only if operational status was up(1) sometime before. (So, do not fire 'ethernal off' interfaces.) WARNING: if closed manually - won't fire again on next poll, because of .diff.{$IFCONTROL:"{#IFNAME}"}=1 and last(/Arista SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}])=2 and (last(/Arista SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#1)<>last(/Arista SNMP/net.if.status[ifOperStatus.{#SNMPINDEX}],#2))AVERAGE ⚠Interface {#IFNAME}({#IFALIAS}): Operational status

Discovery rule №4

NameDescriptionTypeIntervalKey and additional info
EtherLike-MIB DiscoveryDiscovering interfaces from IF-MIB and EtherLike-MIB. Interfaces with up(1) Operational Status are discovered.SNMP_AGENT1hnet.if.duplex.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
Interface {#IFNAME}({#IFALIAS}): Duplex statusMIB: EtherLike-MIB The current mode of operation of the MAC entity. 'unknown' indicates that the current duplex mode could not be determined. Management control of the duplex mode is accomplished through the MAU MIB. When an interface does not support autonegotiation, or when autonegotiation is not enabled, the duplex mode is controlled using ifMauDefaultType. When autonegotiation is supported and enabled, duplex mode is controlled using ifMauAutoNegAdvertisedBits. In either case, the currently operating duplex mode is reflected both in this object and in ifMauType. Note that this object provides redundant information with ifMauType. Normally, redundant objects are discouraged. However, in this instance, it allows a management application to determine the duplex status of an interface without having to know every possible value of ifMauType. This was felt to be sufficiently valuable to justify the redundancy. Reference: [IEEE 802.3 Std.], 30.3.1.1.32,aDuplexStatus.SNMP_AGENT

-

net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
Interface {#IFNAME}({#IFALIAS}): In half-duplex modePlease check autonegotiation settings and cablinglast(/Arista SNMP/net.if.duplex[dot3StatsDuplexStatus.{#SNMPINDEX}])=2WARNING 📢Interface {#IFNAME}({#IFALIAS}): Duplex status

Discovery rule №5

NameDescriptionTypeIntervalKey and additional info
PSU discovery

-

SNMP_AGENT1hpsu.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
{#ENT_NAME}: Power supply statusMIB: ENTITY-STATE-MIBSNMP_AGENT3msensor.psu.status[entStateOper.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
{#ENT_NAME}: Power supply is in critical statePlease check the power supply unit for errorscount(/Arista SNMP/sensor.psu.status[entStateOper.{#SNMPINDEX}],#1,"eq","{$PSU_CRIT_STATUS}")=1AVERAGE ⚠{#ENT_NAME}: Power supply status

Discovery rule №6

NameDescriptionTypeIntervalKey and additional info
Temperature discoveryENTITY-SENSORS-MIB::EntitySensorDataType discovery with temperature filterDEPENDENT0temp.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
{#SENSOR_INFO}: Temperature statusMIB: ENTITY-SENSORS-MIB The operational status of the sensor {#SENSOR_INFO}SNMP_AGENT3msensor.temp.status[entPhySensorOperStatus.{#SNMPINDEX}]
{#SENSOR_INFO}: TemperatureMIB: ENTITY-SENSORS-MIB The most recent measurement obtained by the agent for this sensor. To correctly interpret the value of this object, the associated entPhySensorType, entPhySensorScale, and entPhySensorPrecision objects must also be examined.SNMP_AGENT3msensor.temp.value[entPhySensorValue.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
{#SENSOR_INFO}: Temperature is above the critical thresholdThis trigger uses temperature sensor values defined in the device.min(/Arista SNMP/sensor.temp.value[entPhySensorValue.{#SNMPINDEX}],5m) > {#THRESHOLD_HI_CRIT}HIGH ⛔{#SENSOR_INFO}: Temperature
{#SENSOR_INFO}: Temperature is above the warning thresholdThis trigger uses temperature sensor values defined in the device.min(/Arista SNMP/sensor.temp.value[entPhySensorValue.{#SNMPINDEX}],5m) > {#THRESHOLD_HI_WARN}WARNING 📢{#SENSOR_INFO}: Temperature
{#SENSOR_INFO}: Temperature is below the critical thresholdThis trigger uses temperature sensor values defined in the device.max(/Arista SNMP/sensor.temp.value[entPhySensorValue.{#SNMPINDEX}],5m) < {#THRESHOLD_LO_CRIT}HIGH ⛔{#SENSOR_INFO}: Temperature
{#SENSOR_INFO}: Temperature is below the warning thresholdThis trigger uses temperature sensor values defined in the device.max(/Arista SNMP/sensor.temp.value[entPhySensorValue.{#SNMPINDEX}],5m) < {#THRESHOLD_LO_WARN}WARNING 📢{#SENSOR_INFO}: Temperature

Discovery rule №7

NameDescriptionTypeIntervalKey and additional info
Storage discoveryHOST-RESOURCES-MIB::hrStorage discovery with storage filter.SNMP_AGENT1hvfs.fs.discovery[snmp]

Item prototypes

NameDescriptionTypeIntervalKey and additional info
{#FSNAME}: Space utilizationSpace utilization in % for {#FSNAME}CALCULATED

-

vfs.fs.pused[storageUsedPercentage.{#SNMPINDEX}]
{#FSNAME}: Total spaceMIB: HOST-RESOURCES-MIB The size of the storage represented by this entry, in units of hrStorageAllocationUnits. This object is writable to allow remote configuration of the size of the storage area in those cases where such an operation makes sense and is possible on the underlying system. For example, the amount of main storage allocated to a buffer pool might be modified or the amount of disk space allocated to virtual storage might be modified.SNMP_AGENT

-

vfs.fs.total[hrStorageSize.{#SNMPINDEX}]
{#FSNAME}: Used spaceMIB: HOST-RESOURCES-MIB The amount of the storage represented by this entry that is allocated, in units of hrStorageAllocationUnits.SNMP_AGENT

-

vfs.fs.used[hrStorageUsed.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
{#FSNAME}: Disk space is critically lowTwo conditions should match: First, space utilization should be above {$VFS.FS.PUSED.MAX.CRIT:"{#FSNAME}"}. Second condition should be one of the following: - The disk free space is less than {$VFS.FS.FREE.MIN.CRIT:"{#FSNAME}"}. - The disk will be full in less than 24 hours.last(/Arista SNMP/vfs.fs.pused[storageUsedPercentage.{#SNMPINDEX}])>{$VFS.FS.PUSED.MAX.CRIT:"{#FSNAME}"} and ((last(/Arista SNMP/vfs.fs.total[hrStorageSize.{#SNMPINDEX}])-last(/Arista SNMP/vfs.fs.used[hrStorageUsed.{#SNMPINDEX}]))<{$VFS.FS.FREE.MIN.CRIT:"{#FSNAME}"} or timeleft(/Arista SNMP/vfs.fs.pused[storageUsedPercentage.{#SNMPINDEX}],1h,100)<1d)AVERAGE ⚠
{#FSNAME}: Disk space is lowTwo conditions should match: First, space utilization should be above {$VFS.FS.PUSED.MAX.WARN:"{#FSNAME}"}. Second condition should be one of the following: - The disk free space is less than {$VFS.FS.FREE.MIN.WARN:"{#FSNAME}"}. - The disk will be full in less than 24 hours.last(/Arista SNMP/vfs.fs.pused[storageUsedPercentage.{#SNMPINDEX}])>{$VFS.FS.PUSED.MAX.WARN:"{#FSNAME}"} and ((last(/Arista SNMP/vfs.fs.total[hrStorageSize.{#SNMPINDEX}])-last(/Arista SNMP/vfs.fs.used[hrStorageUsed.{#SNMPINDEX}]))<{$VFS.FS.FREE.MIN.WARN:"{#FSNAME}"} or timeleft(/Arista SNMP/vfs.fs.pused[storageUsedPercentage.{#SNMPINDEX}],1h,100)<1d)WARNING 📢

Discovery rule №8

NameDescriptionTypeIntervalKey and additional info
Memory discoveryHOST-RESOURCES-MIB::hrStorage discovery with memory filterSNMP_AGENT1hvm.memory.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
{#MEMNAME}: Total memoryMIB: HOST-RESOURCES-MIB The size of the storage represented by this entry, in units of hrStorageAllocationUnits. This object is writable to allow remote configuration of the size of the storage area in those cases where such an operation makes sense and is possible on the underlying system. For example, the amount of main memory allocated to a buffer pool might be modified or the amount of disk space allocated to virtual memory might be modified.SNMP_AGENT

-

vm.memory.total[hrStorageSize.{#SNMPINDEX}]
{#MEMNAME}: Used memoryMIB: HOST-RESOURCES-MIB The amount of the storage represented by this entry that is allocated, in units of hrStorageAllocationUnits.SNMP_AGENT

-

vm.memory.used[hrStorageUsed.{#SNMPINDEX}]
{#MEMNAME}: Memory utilizationMemory utilization in %.CALCULATED

-

vm.memory.util[memoryUsedPercentage.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
{#MEMNAME}: High memory utilizationThe system is running out of free memory.min(/Arista SNMP/vm.memory.util[memoryUsedPercentage.{#SNMPINDEX}],5m)>{$MEMORY.UTIL.MAX}AVERAGE ⚠{#MEMNAME}: Memory utilization

Discovery rule №9

NameDescriptionTypeIntervalKey and additional info
Voltage discoveryENTITY-SENSORS-MIB::EntitySensorDataType discovery with volts filterDEPENDENT0voltage.discovery

Item prototypes

NameDescriptionTypeIntervalKey and additional info
{#SENSOR_INFO}: VoltageMIB: ENTITY-SENSORS-MIB The most recent measurement obtained by the agent for this sensor. To correctly interpret the value of this object, the associated entPhySensorType, entPhySensorScale, and entPhySensorPrecision objects must also be examined.SNMP_AGENT

-

sensor.voltage.value[entPhySensorValue.{#SNMPINDEX}]

Trigger prototypes

NameDescriptionExpressionPriorityDependencies
{#SENSOR_INFO}: Voltage is above the critical thresholdThis trigger uses voltage sensor values defined in the device.min(/Arista SNMP/sensor.voltage.value[entPhySensorValue.{#SNMPINDEX}],5m) > {#THRESHOLD_HI_CRIT}HIGH ⛔{#SENSOR_INFO}: Voltage
{#SENSOR_INFO}: Voltage is above the warning thresholdThis trigger uses voltage sensor values defined in the device.min(/Arista SNMP/sensor.voltage.value[entPhySensorValue.{#SNMPINDEX}],5m) > {#THRESHOLD_HI_WARN}WARNING 📢{#SENSOR_INFO}: Voltage
{#SENSOR_INFO}: Voltage is below the critical thresholdThis trigger uses voltage sensor values defined in the device.max(/Arista SNMP/sensor.voltage.value[entPhySensorValue.{#SNMPINDEX}],5m) < {#THRESHOLD_LO_CRIT}HIGH ⛔{#SENSOR_INFO}: Voltage
{#SENSOR_INFO}: Voltage is below the warning thresholdThis trigger uses voltage sensor values defined in the device.max(/Arista SNMP/sensor.voltage.value[entPhySensorValue.{#SNMPINDEX}],5m) < {#THRESHOLD_LO_WARN}WARNING 📢{#SENSOR_INFO}: Voltage